Ultrasonographic measurement of optic nerve sheath diameter to detect raised intracranial pressure in adult head injury patients in the intensive care unit and its correlation with computed tomography scan findings


1 Department of Critical Care Medicine, Tata Memorial Hospital, Mumbai, Maharashtra, India
2 Department of Anaesthesiology and Critical Care, AHRR, New Delhi, India
3 Department of Anaesthesiology and Critical Care, Level III IFH, MONUSCO, Goma, DR Congo
4 Department of Radiology, Ojas Hospital, Panchkula, Haryana, India

Correspondence Address:
Dr. Shibu Sasidharan
E3/601, GH-79, Sector-20, Panchkula - 134 117, Haryana
DR Congo
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/mjhs.mjhs_29_21

Rights and Permissions

Background: Our objective was to evaluate if ultrasonographic measurement of optic nerve sheath diameter can be used for early and accurate diagnosis of raised intracranial pressure as seen in cranial CT scan in patients of traumatic brain injury. Methods: Prospective, observational study. 40 adult traumatic head injury patients with altered sensorium suspected to have elevated intracranial pressure admitted to the ICU. Single optic nerve sheath diameter was measured 3.0 mm behind the globe in each eye, and optic nerve sheath diameter from each eye were averaged to create a binocular optic nerve sheath diameter measurement. A binocular optic nerve sheath diameter or uni-ocular measurement in patients with single eye measurement greater than 5.00 mm was considered abnormal. A CT scan of the head was performed within 2 hrs of USG measurement. The radiologist was blinded to the USG measurement of optic nerve sheath diameter and patient's CT considered to be positive for raised ICP Results: Mean age of the patients was 41.15 years. Mean ONSD recorded was 5.613. Highest ONSD was 6.300 and the lowest was 4.750. CT scan findings of raised ICT were present in 36 patients and mean ONSD was >5.00 mm in all the patients. CT scan finding of raised ICT was not present in 4 patients out of which raised ONSD was present in 1 patient. Hence study showed that USG of ONSD has 100% sensitivity and 75% specificity with a positive predictive value of 97.3% and a negative predictive value of 100%. Conclusions: Bedside ultrasonographic measurement of optic nerve sheath diameter has the potential as a sensitive screening test for elevated intracranial pressure in adult head injury patients in ICU.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed326    
    Printed0    
    Emailed0    
    PDF Downloaded44    
    Comments [Add]    

Recommend this journal